what is a plasma

背面 (解答)

A Plasma is a gas that contains ions and free electrons.

#2
正面 (问题)

what do the free electric charges make the plasma

背面 (解答)

electrically conductive so that it responds strongly to electromagnetic fields.

#3
正面 (问题)

For ICP what is used to produce plasma

背面 (解答)

argon

#4
正面 (问题)

plasma is what?

背面 (解答)

an electrical discharge

#5
正面 (问题)

how is plasma generated

背面 (解答)

through inductive coupling of free electrons with rapidly oscillating external magnetic field (27 MHz) Energy is transferred collisionally to Argon molecules

#6
正面 (问题)

Plasma at atmospheric pressure

背面 (解答)

allows very high temperatures ~ 10000 C (a low pressure plasma is a fluorescent lamp)

#7
正面 (问题)

plasma temp. range

背面 (解答)

between 6 000 K and 10 000 K

#8
正面 (问题)

why use argon plasma

背面 (解答)

inert not expensive obtained at high purity

#9
正面 (问题)

important reasons why argon is plasma

背面 (解答)

first ionization potential of 15.75 eV • Higher than the first ionization potential of most other elements (except He, F and Ne) • Lower than the second ionization potential of most other elements (except Ca, Sr, Ba…)

#10
正面 (问题)

why are analyte elements singly charged

背面 (解答)

because the plasma environment is defined by Ar

#11
正面 (问题)

what happens when a time varying electric current is passed through the coil

背面 (解答)

it creates a time varying magnetic field around it,

#12
正面 (问题)

what does a time varying magnetic field induce

背面 (解答)

electric currents in the rarefied gas, leading to break down and formation of a plasma. - ICP discharges are of relatively high electron density, on the order of 1015 cm-3.

#13
正面 (问题)

3 detection methods

背面 (解答)

ICP - MS : Inductively Coupled Plasma Mass Spectroscopy ICP - OES : Inductively Coupled Plasma Optical Emission Spectrometry = ICP - AES : Inductively Coupled Plasma Atomic Emission Spectrometry

#14
正面 (问题)

what is ICP-OES and ICP-MS used for

背面 (解答)

bulk elemental chemical analysis of just about any material or substance (waters, biological materials, inorganic materials of all sorts, environmental, forensic, geological samples…

#15
正面 (问题)

what can be measured using ICP-OES and ICP-MS

背面 (解答)

most of the periodic table conc. from major to parts per billion or in cases parts per trillion in solution can be measured

#16
正面 (问题)

ICP-AES uses a plasma for what

背面 (解答)

to produce excited atoms that emit electromagnetic radiation at a wavelength characteristic of a particular element.

#17
正面 (问题)

what does the intensity of the emission of electromagnetic radiation indicate from ICP-AES

背面 (解答)

the concentration of the element within the sample.

#18
正面 (问题)

ICP-MS is a technique based on…

背面 (解答)

coupling together an ICP as a method of producing ions with a mass spectrometer as a method of separating and detecting the ions.

#19
正面 (问题)

what is ICP-MS used for

背面 (解答)

quantitative multi-elemental analysis and stable isotopic ratioing that is becoming increasingly important in biotechnology, nanotechnology, biochemistry and analytical chemistry.

#20
正面 (问题)

features of ICP-MS

背面 (解答)

 Excellent detection limit low ppb-ppt for all elements  Wide elemental coverage from Li to U, over 70 elements measurable  All elements determined simultaneously  Wide dynamic range linear over 9 orders  Routine technique can leave system running overnight  Small size instrument saves space in the lab

#21
正面 (问题)

ICP-MS vs. ICP-OES

背面 (解答)

MS much simpler than the optical emission spectra. Most heavy elements exhibit hundreds of emission lines, but they have only 1-10 natural isotopes in the mass spectrum.  ICP-OES suffers from many overlapping spectral interferences from other elements and a very high background emission from the plasma itself, limiting detection limits.  Detection limits of ICP-MS are three orders of magnitude better than ICP-OES.