Back to marketplace

MIDTERM LEC 1.3

No description yet. This curated deck is ready for daily study.

Total cards: 24•Content version: v4•Public deck•Updated: 8/1/2026

Card preview (24)

#1
Front (Question)

CALIBRATION MARKS/DESIGN It delivers the exact amount it holds into a container; should not be blown out

Back (Answer)

To Deliver (TD) Pipette

#2
Front (Question)

CALIBRATION MARKS/DESIGN It is designed to meet the requirements of Class A-type pipettes.

Back (Answer)

To Deliver (TD) Pipette

#3
Front (Question)

CALIBRATION MARKS/DESIGN It is designed to drain by gravity, and the desired volume is obtained when draining stops.

Back (Answer)

To Deliver (TD) Pipette

#4
Front (Question)

CALIBRATION MARKS/DESIGN Proper usage: Hold vertically with the tip against the side of the container and should not touch the accumulating liquid

Back (Answer)

To Deliver (TD) Pipette

#5
Front (Question)

CALIBRATION MARKS/DESIGN To Deliver (TD) Pipette Examples:

Back (Answer)

Serologic, Mohr, and volumetric transfer pipettes

#6
Front (Question)

CALIBRATION MARKS/DESIGN It holds a particular volume but does not dispense the exact volume.

Back (Answer)

To Contain (TC) Pipette

#7
Front (Question)

CALIBRATION MARKS/DESIGN It is also known as the rinse-out pipette.

Back (Answer)

To Contain (TC) Pipette

#8
Front (Question)

CALIBRATION MARKS/DESIGN It does not meet Class A certification criteria.

Back (Answer)

To Contain (TC) Pipette

#9
Front (Question)

CALIBRATION MARKS/DESIGN To Contain (TC) Pipette

Back (Answer)

Sahli hemoglobin and Lang-Levy pipettes

#10
Front (Question)

DRAINAGE CHARACTERISTICS It has continuous etched rings on top or near the mouthpiece of the pipette and exact volume is obtained when the last drop is blown out.

Back (Answer)

Blow-out Pipette

#11
Front (Question)

DRAINAGE CHARACTERISTICS This type of pipette is not rinsed out.

Back (Answer)

Blow-out Pipette

#12
Front (Question)

DRAINAGE CHARACTERISTICS Blow-out Pipette Examples:

Back (Answer)

Ostwald-Folin and serological pipette

#13
Front (Question)

DRAINAGE CHARACTERISTICS ● It allows the liquid to drain by gravity

Back (Answer)

Self-draining

#14
Front (Question)

DRAINAGE CHARACTERISTICS It does not have etched or frosted rings

Back (Answer)

Self draining

#15
Front (Question)

Transfer Pipette for nonviscous fluid; self-draining; small amount left in the tip should not be blown out

Back (Answer)

Volumetric Pipette

#16
Front (Question)

Transfer Pipette for viscous fluid; with etched ring

Back (Answer)

Ostwald Folin

#17
Front (Question)

Transfer Pipette transfers fluids without consideration of a specific volume

Back (Answer)

Pasteur Pipette

#18
Front (Question)

Graduated or Measuring Pipette with graduations to the tip; blow-out pipette

Back (Answer)

Serological Pipette

#19
Front (Question)

Graduated or Measuring Pipette without graduations to the tip; calibrated between 2 marks; self-draining Pipette

Back (Answer)

Mohr Pipette

#20
Front (Question)

Graduated or Measuring Pipette TC pipettes - Glass Micropipettes (< 1 mL) (4)

Back (Answer)

Sahli-Hellige Pipette Lang-Levy Pipette RBC and WBC Pipettes Kirk and Overflow Pipettes

#21
Front (Question)

It relies on piston for suction creation to draw the sample into a disposable tip.

Back (Answer)

Air Displacement Pipette

#22
Front (Question)

The piston does not come in contact with the liquid

Back (Answer)

Air Displacement Pipette

#23
Front (Question)

A disposable, one-time use polypropylene tip is attached to the pipette barrel.

Back (Answer)

Air Displacement Pipette

#24
Front (Question)

It operates by moving the piston in the pipette tip or barrel, much like a hypodermic syringe.

Back (Answer)

Positive Displacement Pipette