[2S] UNIT 8 Glucometer

No description yet. This curated deck is ready for daily study.

Total cards: 24•Content version: v4•Public deck•Updated: 8/1/2026

Card preview (24)

#1
Front (Question)

Point-of-care test for glucose conducted close to the site of patient care

Back (Answer)

Glucometer

#2
Front (Question)

Working principle of a glucometer

Back (Answer)

Electrochemical

#3
Front (Question)

Blood from a capillary puncture is introduced to a film strip comprised of several layers, each with unique function

Back (Answer)

Glucometer

#4
Front (Question)

T/F: Enzymes or enzymatic reaction are better than colorimetric assays in detecting analytes

Back (Answer)

T

#5
Front (Question)

Why is glucometer not the most ideal for glucose when it also detects enzymes?

Back (Answer)

We do not know how much enzymes are in a strip, that’s why we do not use this for FBS

#6
Front (Question)

Enzymes such as glucose oxidase, hexokinase, and glucose dehydrogenase are used with reflectance or electrochemical detection

Back (Answer)

Glucometer

#7
Front (Question)

The area of strip where it contains a reagent and also collects the blood sample. Majority where the chemical reaction takes place

Back (Answer)

Capillary Channel for Sample

#8
Front (Question)

These monitoring devices are used in the home, in the physician’s office, or at the bedside in the hospital to monitor for hypoglycemia and hyperglycemia

Back (Answer)

In vitro diagnostic test systems: Glucometer

#9
Front (Question)

Requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus

Back (Answer)

In vitro diagnostic test systems: Glucometer

#10
Front (Question)

T/F: Glucometer is for screening and confirming DM

Back (Answer)

F; NOT

#11
Front (Question)

Another reason why glucometer is not for screening / confirmatory

Back (Answer)

Whole blood is used, specifically capillary blood. WB - the cells are still in contact w/ extracellular glucose, chances are they will try to metabolise glucose

#12
Front (Question)

T/F: In a finger prick, the depth should not go beyond 2.4 mm, so a 2.2 mm depth maybe used

Back (Answer)

T

#13
Front (Question)

Tends to give approx. 10%-15% lower glucose readings than plasma, but the percentage varies on the basis of hematocrit, analysis technique, and sample timing (fasting vs. postglucose load)

Back (Answer)

Whole Blood

#14
Front (Question)

T/F: Most reference values rely on measurement of the serum / plasma

Back (Answer)

T

#15
Front (Question)

T/F: In capillary puncture, always squeeze the punctured finger to release the blood

Back (Answer)

F, DO NOT SQUEEZE

#16
Front (Question)

What finger should be pricked?

Back (Answer)

Ring / Middle finger

#17
Front (Question)

ADVANTAGES OF A GLUCOMETER T/F: Small blood volume

Back (Answer)

T

#18
Front (Question)

T/F: Once the device touched the drop of blood, it will react with glucose oxidase, hexokinase, and glucose dehydrogenase

Back (Answer)

T

#19
Front (Question)

ADVANTAGES OF A GLUCOMETER T/F: Immediate results—no lab transportation

Back (Answer)

T

#20
Front (Question)

T/F: It is important to wipe the first drop of blood with cotton as it is contaminated with tissue fluid

Back (Answer)

T

#21
Front (Question)

ADVANTAGES OF A GLUCOMETER T/F: Whole blood, urine, and other body fluids analyzed without processing

Back (Answer)

T

#22
Front (Question)

ADVANTAGES OF A GLUCOMETER T/F: Narrow menu of tests available

Back (Answer)

F; Wide menu

#23
Front (Question)

ADVANTAGES OF A GLUCOMETER T/F: Works within clinical patient flow

Back (Answer)

T

#24
Front (Question)

DISADVANTAGES OF A GLUCOMETER T/F: More expensive than traditional laboratory tests

Back (Answer)

T