#1
Front (Question)

It is a technique used to measure current or voltage produced by the activity of an ion

Back (Answer)

Electrochemistry Technique

#2
Front (Question)

What are the 5 techniques under Electrochemistry Technique

Back (Answer)

• Potentiometry • Amperometry • Coulometry • Polarography • Voltammetry

#3
Front (Question)

It measures the VOLTAGE potential at a constant current

Back (Answer)

Potentiometry

#4
Front (Question)

Potentiometry uses (2)

Back (Answer)

pH pCO2

#5
Front (Question)

Potentiometry Reference Electrode (2)

Back (Answer)

• Calomel • Silver-silver Chloride

#6
Front (Question)

Two types of Potentiometry (2)

Back (Answer)

• Direct Ion Selective Electrode • Indirect Ion Selective Electrode

#7
Front (Question)

It measures the DISSOLVED ELECTROLYTES at fluid phase

Back (Answer)

Ion Selective Electrode

#8
Front (Question)

Ion Selective Electrodes depends on the (?)

Back (Answer)

Barrier/Membrane

#9
Front (Question)

What are Barrier/Membrane used by ISE (6)

Back (Answer)

Vice Ganda GONE 1. Vancomycin Gel (Potassium) 2. Glass Aluminum Silicate (Sodium) 3. Gas 4. Organic Ion Liquid exchanger (Calcium and Lithium) 5. Nonactin and Monactin 6. Enzymes

#10
Front (Question)

Interferences condition happens in ISE

Back (Answer)

Protein-coating ISE > Build-up counter-voltage > defective ISE

#11
Front (Question)

Differences of Direct and Indirect ISE

Back (Answer)

DIRECT ISE - w/o sample dilution - not prone to PSEUDOHYPONATREMIA encountered in hyperlipidemic and hypoproteinemia sample INDIRECT ISE - w sample dilution

#12
Front (Question)

It is a electrochemical titration that uses amperometry as a detector

Back (Answer)

COULOMETRY

#13
Front (Question)

Coulometry measure amount of ____ at fixed potential

Back (Answer)

electricity

#14
Front (Question)

Coulometry uses (1)

Back (Answer)

Chloride Test

#15
Front (Question)

Chloride Test sample spx (3)

Back (Answer)

CSF Serum Sweat

#16
Front (Question)

Coulometry Sweat spx is for the diagnosis of

Back (Answer)

Cystic Fibrosis

#17
Front (Question)

Coulometry Interferences

Back (Answer)

BC, CYS Bromide Cyanide Cysteine

#18
Front (Question)

It measures differences in CURRENT FLOW produced by oxidation-reduction reaction

Back (Answer)

Amperometry

#19
Front (Question)

Amperometry uses (4)

Back (Answer)

“APO2” - si apo mahilig sa Sweet Chocolate Pie • pO2 • Glucose • Chloride • Peroxidase determination

#20
Front (Question)

It measures the differences in CURRENT at a constant voltage

Back (Answer)

Polarography

#21
Front (Question)

Amount of Increase in current is ______ proportional to the analyte concentration

Back (Answer)

Directly Proportional

#22
Front (Question)

It measures the differences in CURRENT AFTER POTENTIAL APPLICATION

Back (Answer)

Voltammetry

#23
Front (Question)

Voltammetry Technique used for Lead and Iron Testing

Back (Answer)

Anodic Stripping Voltammetry