#1
Front (Question)

what are the seven crystal systems ?

Back (Answer)

cubic tetragonal orthorhombic monoclinic triclinic trigonal hexagonal

#2
Front (Question)

what does polymorphism mean ?

Back (Answer)

elements can have a different crystal system depending on the temperature

#3
Front (Question)

what do the diffractograms of single crystals, polycrystalline and amorphous materials look like ?

Back (Answer)

single -> regularly spaced dots poly -> concentric circles amorphous -> faded circle

#4
Front (Question)

explain the formation of a diffraction pattern (several peaks)

Back (Answer)

the peaks are constructive interference between 2 reflective waves (x-ray beams) on 2 consecutive planes. Several peaks because multiple reflection planes in a lattice

#5
Front (Question)

explain the principle of an XRD measurement

Back (Answer)

we shine x-ray beams on a specimen at a certain angle -> we detect the reflected waves if they are coherent (constructive interference)

#6
Front (Question)

list the components (5) of an XRD system and explain function

Back (Answer)

• x-ray tube = source of x-rays • x-ray optics = condition the beam before it hits the sample • goniometer = platform that holds and moves the sample, optics, detector and/or tube • x-ray optics = condition the beam after it encountered the sample • detector = count the number of scattered x-rays

#7
Front (Question)

Bragg equation ?

Back (Answer)

2dsin(theta) = n*lambda d is the spacing between the planes n is the order of diffraction lambda is the wavelength

#8
Front (Question)

how is the diffractogram influenced by : lattice paramater, crystallite size, atomic number

Back (Answer)

• increase lattice parameter = angles decrease • increase crystallite size = same angles but higher intensity, if very small -> tends to amorphous (scherrer equation) • intensity is proportional to atomic number

#9
Front (Question)

describe the functionality of a SEM, what can we see ?

Back (Answer)

Interaction of fast electrons with a sample : - backscattered electrons : atomic number contrast (heavy = bright), a bit deeper than surface - secondary electrons : topography contrast, come from surface - photons : for EDX, the deepest

#10
Front (Question)

demonstrate usefulness of BSE and EDX detectors

Back (Answer)

we can combine the info from BSE and EDX to map a whole surface : see where the heavy / light elements are, see each individual elements

#11
Front (Question)

explain creation of an EDX mapping

Back (Answer)

when shooting electrons to a sample, there is a photon released -> creates energy peaks depending on the element. We can map a surface that way, to find out where each element is

#12
Front (Question)

what is the depth of info in SEM/EDX ?

Back (Answer)

the depth is around 0.5 to 2 micro meters.

#13
Front (Question)

explain the photoelectric effect, minimum frequency ?

Back (Answer)

shine light on a surface (= emits photons) -> if the photons have a high enough energy, they will kick out electrons from the sample. The minimum frequency / max wavelength is element dependent

#14
Front (Question)

explain the principle of UV and X-Ray photoelectron spectroscopy

Back (Answer)

we shine light of a sample, and depending on the kinetic energy of the resulting electrons, we can find their binding energy h*f = Ek + Eb (+work) UV -> electrons in valence band X-ray -> electrons in core levels

#15
Front (Question)

describe how XPS spectra are aquired and interpreted

Back (Answer)

We get the binding energy of the electrons from the surface of the material. It also gives info on what kind of bonds are present in the material (electron transfers change the bonding energy).

#16
Front (Question)

tell about the surface sensitivity of XPS

Back (Answer)

it only goes about 100 angstrom deep. The x-ray beam can penetrate further but the deep electrons won’t have the energy to emerge from the surface.

#17
Front (Question)

discuss the idea of angle resolved XPS measurement

Back (Answer)

the smaller the angle between the detector and sample, the smaller the information depth (because electrons have to travel a longer distance). Grazing angle -> only top layer.

#18
Front (Question)

in what condition is XPS perfomed ?

Back (Answer)

ultra high vacuum because electrons can’t travel in air

#19
Front (Question)

how does the applied voltage affect the current in photoelectric effect ?

Back (Answer)

A negative voltage will slow down the elctrons (lower current). If too negative, current is zero, then it increases until the saturation current. After saturation, an increase in voltage will not change the current.