Blood Glucose Estimation Test (M)

No description yet. This curated deck is ready for daily study.

Total cards: 24•Content version: v4•Public deck•Updated: 8/1/2026

Card preview (24)

#1
Front (Question)

True or False. Glucose test is not routinely performed in the lab

Back (Answer)

False, because it is routinely performed in the lab

#2
Front (Question)

What clinical disorder can be diagnosed via glucose test?

Back (Answer)

Diabetes mellitus

#3
Front (Question)

What is the reference range for glucose test?

Back (Answer)

70 - 100 mg/dL

#4
Front (Question)

What is the unit for glucose test?

Back (Answer)

mg/dL

#5
Front (Question)

What are the sxs that can be used for glucose test?

Back (Answer)

1) Fasting venous plasma 2) Random Blood Sugar (RBS) 3) CSF 4) Synovial fluid 5) Serous fluid 6) Urine

#6
Front (Question)

What is the required time of fasting for fasting venous plasma sx?

Back (Answer)

8 - 10 hrs

#7
Front (Question)

What happens if the sx is unrefrigerated (there is a delay in testing)?

Back (Answer)

Decreases 7 mg/dL per hr

#8
Front (Question)

What happens if the sx is refrigerated (test can’t be done promptly)?

Back (Answer)

Decreases 2 mg/dL per hr

#9
Front (Question)

What is the result if whole blood is used as sx for glucose testing?

Back (Answer)

10 - 15% lower

#10
Front (Question)

The results if whole blood is used for glucose testing is lower than what?

Back (Answer)

Than serum and plasma

#11
Front (Question)

What is the percentage of the plasma concentrations of CSF?

Back (Answer)

60 - 70%

#12
Front (Question)

How to prevent the loss of glucose (in glucose test)?

Back (Answer)

Plasma glucose should be separated within an hour

#13
Front (Question)

What etubes should be used if glucose testing will be delayed?

Back (Answer)

Red, yellow, and gray tops

#14
Front (Question)

True or False. Venous blood glucose is higher than capillary blood (RBS)

Back (Answer)

False, because venous blood glucose is lower than capillary blood (RBS)

#15
Front (Question)

How high or how low is venous blood glucose compared to capillary blood (RBS)?

Back (Answer)

It is lower than 7 mg/dL compared to capillary blood (RBS)

#16
Front (Question)

What tube is preferred to be used for glucose test?

Back (Answer)

Gray top

#17
Front (Question)

Why is gray top preferred to be used for glucose test?

Back (Answer)

Because it contains potassium oxalate / sodium fluoride

#18
Front (Question)

What is the action of enolase?

Back (Answer)

It inhibits glycolytic enzyme

#19
Front (Question)

2 mg of NaF per mL of blood prevents what?

Back (Answer)

It prevents glycolysis up to 48 hrs

#20
Front (Question)

What is the action of fluoride (sodium fluoride)?

Back (Answer)

It binds w/ magnesium w/c causes inhibition of enzyme enolase

#21
Front (Question)

What are the 2 types of methods of glucose estimation test?

Back (Answer)

1) Chemical method 2) Enzymatic method

#22
Front (Question)

What are the different methods under chemical method of glucose estimation test?

Back (Answer)

1) Oxidation - reduction 2) Hagedorn Jensen 3) Condensation method

#23
Front (Question)

What are the different methods under oxidation - reduction of glucose estimation test?

Back (Answer)

1) Folin-Wu 2) Nelson-Somogyi 3) Neocuprione (Neocupreine) method 4) Benedict’s method

#24
Front (Question)

What is the principle of oxidation - reduction?

Back (Answer)

The ability of glucose to directly reduce cupric ions to monovalent cuprous ions in the presence of heat