Back to marketplace

ATOMIC STRUCTURE

No description yet. This curated deck is ready for daily study.

Total cards: 24•Content version: v4•Public deck•Updated: 8/1/2026

Card preview (24)

#1
Front (Question)

what can mass spec be used for?

Back (Answer)

 find the abundance and mass of each isotope in an element allowing us to determine its relative atomic mass  find the relative molecular mass of substances made of molecules.

#2
Front (Question)

what happens in ToF mass spec?

Back (Answer)

particles of the substance are ionised to form 1+ ions which are accelerated so that they all have the same kinetic energy. The time taken to travel a fixed distance is then used to find the mass of each ion in the sample.

#3
Front (Question)

what are the 2 ways of ionising a sample?

Back (Answer)

• electron spray - electron gun

#4
Front (Question)

describe the steps in electron impact ionisation?

Back (Answer)

1- The sample being analysed is vaporised and then high energy electrons are fired at it. 2- The high energy electrons come from an ‘electron gun’ which is a hot wire filament with a current running through it that emits electrons. 3- This usually knocks off one electron from each particle forming a 1+ ion. 4-The 1+ ions are then attracted towards a negative electric plate where they are accelerated.

#5
Front (Question)

what is the equation for an element being analysed via electron impact?

Back (Answer)

X(g) –> X+(g) + e–

#6
Front (Question)

why do we use electron impact ionisation to ionise some molecules?

Back (Answer)

This technique is used for elements and substances with low formula mass (that can be inorganic or organic molecules).

#7
Front (Question)

what is the product formed from electron impact ionisation

Back (Answer)

When molecules are ionised in this way, the 1+ ion formed is known as a molecular ion

#8
Front (Question)

what other than molecular ions appear on the mass spec?

Back (Answer)

The molecular ion often breaks down into smaller fragments some of which are also detected in the mass spectrum.

#9
Front (Question)

describe the steps of electron spray ionisation

Back (Answer)

1- The sample X is dissolved in a volatile solvent (eg water or methanol) and injected through a fine hypodermic needle to give a fine mist (aerosol). 2- The tip of the needle is attached to the positive terminal of a high-voltage power supply. 3- The particles are ionised by gaining a proton (ie an H+ ion which is simply one proton) from the solvent as they leave the needle producing XH+ ions (ions with a single positive charge and a mass of Mr + 1). 4- The solvent evaporates away while the XH+ ions are attracted towards a negative plate where they are accelerated.

#10
Front (Question)

what is the equation for samples being analysed by electron spray?

Back (Answer)

X(g) + H+ –> XH+(g)

#11
Front (Question)

what types of substances do we use electron spray to analyse?

Back (Answer)

This technique is used for many substances with higher molecular mass including many biological molecules such as proteins. This is known as a ‘soft’ ionisation technique and fragmentation rarely takes place.

#12
Front (Question)

what are the 4 stages of ToF?

Back (Answer)

1- ionisation 2-acceleration 3-flight tube 4-detection

#13
Front (Question)

how are positive ions accelerated?

Back (Answer)

using an electric field?

#14
Front (Question)

why are positive ions accelerated?

Back (Answer)

so that they all have the same kinetic energy.

#15
Front (Question)

what does this equation stand for and what are the units: KE = 1/2mv^2?

Back (Answer)

KE = kinetic energy of particle (J) m = mass of the particle (kg) 𝑣 = velocity of the particle (m s–1)

#16
Front (Question)

make velocity the subject of this equation KE = 1/2mv^2?

Back (Answer)

𝒗 = √(𝟐𝑲𝑬)/m

#17
Front (Question)

when particles have the same energy, what does velocity depend on?

Back (Answer)

its mass

#18
Front (Question)

how does mass of a particle effect its speed?

Back (Answer)

Lighter particles have a faster velocity, and heavier particles have a slower velocity.

#19
Front (Question)

how do the positive ions travel through through the flight tube?

Back (Answer)

The positive ions travel through a hole in the negatively charged plate into a tube.

#20
Front (Question)

what does the ToF of each particle depend on?

Back (Answer)

The time of flight of each particle through this flight tube depends on its velocity which in turn depends on its mass.

#21
Front (Question)

what equations are used to calculate ToF along a flight tube?

Back (Answer)

t=d/v t=𝒅√(𝒎/𝟐𝑲E) t = time of flight (s) d = length of flight tube (m) 𝑣 = velocity of the particle (m s–1) m = mass of the particle (kg) KE = kinetic energy of particle (J)

#22
Front (Question)

what /does t=𝒅√(𝒎/𝟐𝑲E) show

Back (Answer)

This shows that the time of flight is proportional to the square root of the mass of the ions. Therefore lighter ions travel faster and reach the detector in less time than the heavier particles that move slower and take longer to reach the detector

#23
Front (Question)

in what order do ions of the isotopes of 24Mg+, 25Mg+,26Mg+ reach the detector and why?

Back (Answer)

1=24Mg+ 2= 25Mg+ 3=26Mg+ in order of mass, lighter= faster

#24
Front (Question)

describe what happens in the detection stage of ToF?

Back (Answer)

The positive ions hit a negatively charged electric plate. When they hit the detector plate, the positive ions are discharged by gaining electrons from the plate. This generates a movement of electrons and hence an electric current that is measured. The size of the current gives a measure of the number of ions hitting the plate.