Back to marketplace

Short as possible GAS ANALYSIS ppt

No description yet. This curated deck is ready for daily study.

Total cards: 24•Content version: v4•Public deck•Updated: 8/1/2026

Card preview (24)

#1
Front (Question)

What are the different types of organic and inorganic Gas Analysis

Back (Answer)

Gas liquid chromatography INFRARED ANALYSIS Mass spectrometry Raman Scattering Piezoelectric analysis Interferometry-refractomer

#2
Front (Question)

All electromagnetic radiation, thus visible light, ultra violet light, and infrared light may be ______, _______, or ______ by matter

Back (Answer)

reflected transmitted absorbed

#3
Front (Question)

Oxygen, CO2, and Anesthetic agents are what ?

Back (Answer)

Matter

#4
Front (Question)

Electromagnetic radiation can be converted into other forms of energy such as ____, _____, and _______

Back (Answer)

electricity (gas discharge) Heat (incandescence) Chemical (Photoluminescense)

#5
Front (Question)

Types of O2 analysis systems

Back (Answer)

GALVANIC CELL (FUEL CELL) POLAROGRAPHIC ELECTRODE PARAMAGNETIC O2 SENSOR fluorescence-quenching pH optode

#6
Front (Question)

Galvnic (fuel cell) • Membrane permable to what? • At the cathode ____ molecules are reduced to H+ • At the Anode____ ions give up electrons • an electron flow b/t the lead ____ and the gold _____ is generated in a K+ hydroxidesolution

Back (Answer)

• Gasses (not liquid) • oxygen • hydroxide • anode cathode

#7
Front (Question)

Galvnic (fuel cell)

Back (Answer)

#8
Front (Question)

Main concept of Galvanic fuel cell

Back (Answer)

Continual consumption = limited life

#9
Front (Question)

Clark polarographic Oxygen electrode • Consist if a _____ source and a _____ meter connecting platinum and silver electrodes • the electrodes are immersed in an _______ cell • an ___permeable membrane (not electrolyte) covers one surface of the cell

Back (Answer)

• Voltage current • electrolyte 3.

#10
Front (Question)

I give up just doing the highlightes he said I am running out of time sorry for this…

Back (Answer)

sorry again

#11
Front (Question)

what is the only thing that exist in the world

Back (Answer)

energy (matter is just energy at rest)

#12
Front (Question)

Infrared Absorption analysis molecules may absorb infrared light if they are _____ and _____

Back (Answer)

Polyatomic and asymetric

#13
Front (Question)

Infrared Absorption analysis advantages

Back (Answer)

anesthestic gasses can be measured

#14
Front (Question)

Infrared Absorption analysis disadvantage

Back (Answer)

symmetric molecules such as O2, N2 and Helium will not be detected

#15
Front (Question)

What is the #1 way we measure anesthetic gases (don’t say mass spec)

Back (Answer)

#16
Front (Question)

what is needed for mass spectrometry

Back (Answer)

a dedicated room due to large size of equipment

#17
Front (Question)

how does infrared absorption analysis

Back (Answer)

the freq absorbed tells you what gas, the amount absorbed tells you how much gas in absorbed

#18
Front (Question)

difference b/t raman scattering and infrared

Back (Answer)

raman- looks at freq of what is changed Infrared looks at freq missing

#19
Front (Question)

what is the 2nd most common monitoring system for gases

Back (Answer)

raman scattering

#20
Front (Question)

advantages of Raman scattering

Back (Answer)

real time results accurate identifies all VAAs only reuirs molecules to be polyatomic (can identify O2 and N2O with sole exception)

#21
Front (Question)

disadvantages of Raman scattering

Back (Answer)

#22
Front (Question)

******* the majority of gas analyzers used in the operating rooms are _____ ____ or _____ _____ for oxygen ,measurement

Back (Answer)

galvanic cell or paramagnetic sensors

#23
Front (Question)

the main analyzer for N20, CO2, anesthetic Gases in the OR is ______ _______ _______ ______

Back (Answer)

#24
Front (Question)

What system uses O2, anode, Cathode, spontaneous electrical current, continual consumption

Back (Answer)

Galvanic Cell (fuel cell)