#1
Front (Question)

Ability of analytical method to measure the smallest concentration of analyte

Back (Answer)

Sensitivity

#2
Front (Question)

Ability of analytical method to measure only the analyte of interest

Back (Answer)

Specidicity

#3
Front (Question)

Nearness or closeness of the assayed value to the true or target value

Back (Answer)

Accuracy

#4
Front (Question)

Ability of analytical method to give repeated results on the same sample

Back (Answer)

Precision or Reproducivility

#5
Front (Question)

Degree by which a method is easily repeated

Back (Answer)

Practicability

#6
Front (Question)

Ability to maintain accuracy and precision over an extended period of time

Back (Answer)

Reliability

#7
Front (Question)

Ability of analytical method to detect proportion of individuals without the disease

Back (Answer)

Diagnostic Specificity

#8
Front (Question)

Ability of analytical method to detect proportion of individuals with the disease

Back (Answer)

Diagnostic Sensitivity

#9
Front (Question)

Sensitivity (%)

Back (Answer)

100 x number of true positive / total number of diseased

#10
Front (Question)

Specificity (%)

Back (Answer)

100 x number of true negative / total number of without disease

#11
Front (Question)

Error due to chance, varies from sample to sample

Back (Answer)

Random Error

#12
Front (Question)

Due to instrument, operator and environmental conditions such as: > pipetting error > mislabeling of samples > temperature fluctuation > improper mixing of sample and reagent

Back (Answer)

Random Error

#13
Front (Question)

Error that influences observations consistently in one direction

Back (Answer)

Systematic Error

#14
Front (Question)

Due to: - Calibration problems - Deterioration of reagents and control materials - Improperly made standard solutions - Contaminated solutions - Unstable and Inadequate reagent blanks - Leaky ion selective electrode - Failing instrumentation and - Poorly written procedures

Back (Answer)

Systematic Error

#15
Front (Question)

Difference between the target value and the assayed value

Back (Answer)

Constant Error

#16
Front (Question)

Results in greater deviation from the target value due to higher sample concentration

Back (Answer)

Proportional/ Slope/ Percent Error

#17
Front (Question)

Highest frequency of Clerical errors occurs with

Back (Answer)

Use of handwritten labels and Request forms

#18
Front (Question)

Objectives of Quality Control

Back (Answer)

• Check stability of the machine • Check quality of reagents • Check technical errors

#19
Front (Question)

Levels of control solutions in General Chemistry

Back (Answer)

TWO levels

#20
Front (Question)

Levels of control solutions in Immunoassays

Back (Answer)

THREE levels

#21
Front (Question)

Characteristics of an Ideal QC material

Back (Answer)

• Resembles human sample • Inexpensive and stable for long periods • No communicable diseases • No matrix effects • With known analyte concentrations • Convenient packaging for easy dispensing and storage

#22
Front (Question)

Incorrect patient identification Improper patient preparation Incorrect specimen collection Mislabeled specimen Incorrect order of draw Incorrect used of tubes for blood collection Incorrect anticoagulant to blood ratio Improper mixing of blood and anticoagulant Incorrect specimen preservation Mishandled specimen Incorrectly interpreted/ ordered laboratory test Incomplete centrifugation Incorrect data login

Back (Answer)

Pre-Analytical Errors

#23
Front (Question)

Incorrect sample and reagent volume Incorrect incubation of solution Equipment/ Instrument malfunction Improper calibration of equipment/ Calibration errors

Back (Answer)

Analytical Errors

#24
Front (Question)

Unavailable or delayed laboratory results Long turnaround time Incomplete laboratory results Wrong transcription of the patient’s data and laboratory results Missing laboratory results Laboratory results submitted to the wrong physician/ doctors who did not request for the lab test

Back (Answer)

Post-analytical Errors